Vertical Axial Flow. 9/9 Pump Dimensions. Mount Plate Dimensions
Note: On water lubricated pumps, the length of column sections (B1) is limited to 1.22 metres, to allow for inclusion of a Centre Bearing Holder (A5) between each flange. Bearings are required at each column flange, except the lowest, which is adjacent to the bottom assembly. If the topmost column section is shorter than 1.22 metres, a bearing will not be required under the Discharge Head. |
|
|
ITEM |
mm |
|
ITEM |
mm |
|
ITEM |
mm |
||||||
A |
Impeller
Diameter |
228.6 |
M |
Stator
Flange PCD |
279.4 |
Y |
Disch
Bolts EW or TDC |
(TDC) |
||||||
B |
Column
Diameter |
228.6 |
N |
Stator
Flange Hole Dia. |
14.3 |
Z |
Disch
Flng No of Bolts |
(8) |
||||||
C |
Bellmouth
Diameter |
381 |
O |
Column
Flange OD |
304.8 |
A1 |
Head
Height |
406.4 |
||||||
D |
1
Stage Length |
262 |
P |
Column
Flange PCD |
279.4 |
A2 |
Disch
C/L Height |
241.3 |
||||||
E |
2
Stage Length |
596.6 |
Q |
Column
Flange Hole Dia. |
14.3 |
A3 |
Flng
Face to Vert C/L |
247.3 |
||||||
F |
Bellmouth
Length |
127 |
R |
Mount
Plate Square |
533.4 |
A4 |
Strainer
Length |
190 |
||||||
G |
Running
Ring Length |
95.3 |
S |
Mount
Plate Thickness |
12.7 |
A5 |
Centre
Brg Holder Thkns |
12.7 |
||||||
H |
Stator
Length |
139.7 |
T |
Mount
Plate Hole Crs. |
482.6 |
A6 |
Support
Channel |
50.8 |
||||||
I |
Adaptor
Length |
-812.8 |
U |
Mount
Plate Hole Dia. |
17.5 |
A7 |
Drive
Column Dia. |
152.4 |
||||||
J |
Impeller
Shaft Length |
812.8 |
V |
Discharge
Flange OD |
311.2 |
A8 |
Extension
Gland Stool |
381 |
||||||
K |
Impeller
Shaft Diameter |
31.75 |
W |
Discharge
Flange PCD |
279.4 |
|
|
|
||||||
L |
Stator
Flange Diameter |
304.8 |
X |
Disch
Flng Hole Dia. |
14.3 |
|
Head
Casting Mtl |
(CI) |
||||||
B1 |
Column |
Water Lube |
305 |
610 |
914 |
1219 |
|
|
|
|||||
Oil Lube |
305 |
610 |
914 |
1219 |
2438 |
|
|
|||||||
B2 |
Extended
Drive Column |
Water Lube |
305 |
610 |
914 |
1219 |
|
|
|
|||||
Oil Lube |
305 |
610 |
914 |
1219 |
2438 |
|
|