Vertical Axial Flow.        9/9  Pump Dimensions.       Mount Plate Dimensions

Note:  On water lubricated pumps, the length of column sections (B1) is limited to 1.22 metres, to allow for inclusion of a Centre Bearing Holder (A5) between each flange.  Bearings are required at each column flange, except the lowest, which is adjacent to the bottom assembly.  If the topmost column section is shorter than 1.22 metres, a bearing will not be required under the Discharge Head.

 

ITEM

mm

 

ITEM

mm

 

ITEM

mm

A

Impeller Diameter

228.6

M

Stator Flange PCD

279.4

Y

Disch Bolts EW or TDC

(TDC)

B

Column Diameter

228.6

N

Stator Flange Hole Dia.

14.3

Z

Disch Flng No of Bolts

(8)

C

Bellmouth Diameter

381

O

Column Flange OD

304.8

A1

Head Height

406.4

D

1 Stage Length

262

P

Column Flange PCD

279.4

A2

Disch C/L Height

241.3

E

2 Stage Length

596.6

Q

Column Flange Hole Dia.

14.3

A3

Flng Face to Vert C/L

247.3

F

Bellmouth Length

127

R

Mount Plate Square

533.4

A4

Strainer Length

190

G

Running Ring Length

95.3

S

Mount Plate Thickness

12.7

A5

Centre Brg Holder Thkns

12.7

H

Stator Length

139.7

T

Mount Plate Hole Crs.

482.6

A6

Support Channel

50.8

I

Adaptor Length

-812.8

U

Mount Plate Hole Dia.

17.5

A7

Drive Column Dia.

152.4

J

Impeller Shaft Length

812.8

V

Discharge Flange OD

311.2

A8

Extension Gland Stool

381

K

Impeller Shaft Diameter

31.75

W

Discharge Flange PCD

279.4

 

 

 

L

Stator Flange Diameter

304.8

X

Disch Flng Hole Dia.

14.3

 

Head Casting Mtl

(CI)

B1

Column

Water Lube

305

610

914

1219

 

 

 

Oil  Lube

305

610

914

1219

2438

 

 

B2

Extended Drive Column

Water Lube

305

610

914

1219

 

 

 

Oil  Lube

305

610

914

1219

2438