Axial Flow Pumps.   Vertical Application.      5/6  Pump Dimensions.
NOTE:  This size is usually supplied as a 'Portax' portable pump.

Note:  On water lubricated pumps, the length of column sections (B1) is limited to 1.22 metres, to allow for inclusion of a Centre Bearing Holder (A5) between each flange.  Bearings are required at each column flange, except the lowest, which is adjacent to the bottom assembly.  If the topmost column section is shorter than 1.22 metres, a bearing will not be required under the Discharge Head.

 

ITEM

mm

 

ITEM

mm

 

ITEM

mm

A

Impeller Diameter

127

M

Stator Flange PCD

177.8

Y

Disch Bolts EW or TDC

(E-W)

B

Column Diameter

152.4

N

Stator Flange Hole Dia.

11.1

Z

Disch Flng No of Bolts

(8)

C

Bellmouth Diameter

304.8

O

Column Flange OD

228.6

A1

Head Height

270

D

1 Stage Length

479.4

P

Column Flange PCD

203.2

A2

Disch C/L Height

152.4

E

2 Stage Length

368.3

Q

Column Flange Hole Dia.

11.1

A3

Flng Face to Vert C/L

152.4

F

Bellmouth Length

127

R

Mount Plate Square

457.2

A4

Strainer Length

152.4

G

Running Ring Length

-

S

Mount Plate Thickness

12.7

A5

Centre Brg Holder Thkns

12.7

H

Stator Length

114.3

T

Mount Plate Hole Crs.

406.4

A6

Support Channel

50.8

I

Adaptor Length

228.6

U

Mount Plate Hole Dia.

14.3

 

 

 

J

Impeller Shaft Length

228.6

V

Discharge Flange OD

228.6

 

 

 

K

Impeller Shaft Diameter

19.1

W

Discharge Flange PCD

203.2

 

 

 

L

Stator Flange Diameter

203.2

X

Disch Flng Hole Dia.

11.1

 

Head Casting Mtl

Cast Al

B1

Column

Water Lube

305

610

914

1219

 

 

 

Oil  Lube

305

610

914

1219

2438

 

 

B2

Extended Drive Column

Water Lube

305

610

914

1219

 

 

 

Oil  Lube

305

610

914

1219

2438