Axial Flow Pumps.   Vertical Application.         4/4  Pump Dimensions.
NOTE:  This size is usually supplied as a 'Portax' portable pump.

Note:  On water lubricated pumps, the length of column sections (B1) is limited to 1.22 metres, to allow for inclusion of a Centre Bearing Holder (A5) between each flange.  Bearings are required at each column flange, except the lowest, which is adjacent to the bottom assembly.  If the topmost column section is shorter than 1.22 metres, a bearing will not be required under the Discharge Head.

 

ITEM

mm

 

ITEM

mm

 

ITEM

mm

A

Impeller Diameter

101.6

M

Stator Flange PCD

155.6

Y

Disch Bolts EW or TDC

(E-W)

B

Column Diameter

101.6

N

Stator Flange Hole Dia.

11.1

Z

Disch Flng No of Bolts

(6)

C

Bellmouth Diameter

228.6

O

Column Flange OD

162.6

A1

Head Height

273

D

1 Stage Length

209.6

P

Column Flange PCD

142.9

A2

Disch C/L Height

209.5

E

2 Stage Length

311.2

Q

Column Flange Hole Dia.

11.1

A3

Flng Face to Vert C/L

146

F

Bellmouth Length

98.4

R

Mount Plate Square

242.9

A4

Strainer Length

115

G

Running Ring Length

-

S

Mount Plate Thickness

12.7

A5

Centre Brg Holder Thkns

12.7

H

Stator Length

104.8

T

Mount Plate Hole Crs.

292.1

A6

Support Channel

50.8

I

Adaptor Length

-

U

Mount Plate Hole Dia.

14.3

 

 

 

J

Impeller Shaft Length

228.6

V

Discharge Flange OD

165.1

 

 

 

K

Impeller Shaft Diameter

19.1

W

Discharge Flange PCD

142.9

 

 

 

L

Stator Flange Diameter

177.8

X

Disch Flng Hole Dia.

11.1

 

Head Casting Mtl

Cast Al

B1

Column

Water Lube

305

610

914

1219

 

 

 

Oil  Lube

305

610

914

1219

2438

 

 

B2

Extended Drive Column

Water Lube

305

610

914

1219

 

 

 

Oil  Lube

305

610

914

1219

2438