Axial Flow Pumps.  Angle Application.
17/21  Pump Dimensions.
                                                                             click here for Extended Drive Column.

Note:  On water lubricated pumps, the length of column sections (B1) is limited to 1.22 metres, to allow for inclusion of a Centre Bearing Holder (A5) between each flange.  Bearings are required at each column flange, except the lowest, which is adjacent to the bottom assembly.  If the topmost column section is shorter than 1.22 metres, a bearing will not be required under the Discharge Head.

 

ITEM

mm

 

ITEM

mm

 

ITEM

mm

A

Impeller Diameter

431.8

M

Stator Flange PCD

495.3

Y

Disch Bolts EW or TDC

(TDC)

B

Column Diameter

533.4

N

Stator Flange Hole Dia.

17.5

Z

Disch Flng No of Bolts

(16)

C

Bellmouth Diameter

685.8

O

Column Flange OD

635

A1

Head Height

1238

D

1 Stage Length

654

P

Column Flange PCD

590.6

A2

Disch C/L Height

317

E

2 Stage Length

942

Q

Column Flng Hole Dia.

17.5

A3

Flng Face to Vert C/L

916

F

Bellmouth Length

209.6

R

Knee Brace Length

533

A4

Strainer Length

343

G

Running Ring Length

104.8

S

Pivot Adjustment Crs.

64

A5

Centre Brg Holder Thkns

19.1

H

Stator Length

182.6

T

Pivot Height

432

A6

Knee Brace Bolt Crs.

381

I

Adaptor Length

152.7

U

Knee Brace Height

533

A7

Drive Column Dia.

355.6

J

Impeller Shaft Length

812.8

V

Discharge Flange OD

642.9

A8

Extension Gland Stool

381

K

Impeller Shaft Diameter

44.45

W

Discharge Flange PCD

590.6

 

 

 

L

Stator Flange Diameter

533.4

X

Dischg Flng Hole Dia.

17.5

 

Knee Brace Channel

5x2.5”

B1    Standard Column Lengths

Water Lube

305

610

914

1219

 

Oil  Lube

305

610

914

1219

2438